Alecta Posterior Lumbar Interbody Fusion Peek Cage (PLIF)
Homepage / Spine Systems / Lumbar Cage Systems / Alecta Posterior Lumbar Interbody Fusion Peek Cage (PLIF)
Lumbar Peek Cage (PLIF)
Alecta Lumbar Peek Cage is manufactured from MRI and CT-compatible PEEK material, which does not result in permanent lesions. PLIF is particularly useful for the elimination of neurological compression and for the correction of degenerative lumbar deformities such as spondylolisthesis, scoliosis, or disc space collapse. It has a serrated structure that allows for clinging to the superior and inferior surfaces. The proximal and distal surfaces of the cage are designed in an inverse v-woven pattern to prevent its dislocation. Adequate spacing over the cage allows for achieving the intended fusion by using the grafting technique. In this product group, two different PLIF Cages are available.
- PLIF Cage
- Expandable PLIF Cage
Indications
- Disc herniation
- Degenerative discopathy and instability
- Restoration of the disc height
General Features of the Products
- Anatomical design allowing for proper fitting to the endplates
- Evenly distribution of the load
- Restoration of lordosis
- Serrated surface
- Titanium marking rod
- A 2°-inclination in the design for anatomical fit
- Operational efficiency and flexibility
- Easy and convenient use
- Proper interior design for grafting
Surgical Technique
1.The patient is positioned appropriately depending on the pathological condition and to allow for performing the Smith Robinson technique. After starting monitorization of the patient, placing the cannulas, and administering anaesthesia; the patient is brought to the supine position. Care should be exercised about the potential pressure points and the back of the patient during positioning. Consequently, the surgical site is prepared by using sterile covers and drapes in compliance with the general procedures.
2.Skin and subcutaneous tissues are incised at the surgical site. The skin and subcutaneous tissue are incised via a hemi-collar skin incision (on the right side of the patient). The platysma is incised vertically. Thus, the prevertebral fascia is exposed.
3. The space is examined by using a C-arm scopy (mobile C-arm X-ray unit). Discectomy is performed to clear the space around. The osteophytes and disk fragments are removed by using a curette.
4.Of different sizes of ALECTA Interbody Lumbar Prosthesis, the appropriate one for the intended surgical site is selected and implanted under C-arm scopy.
5.Consequently, the surgical site is closed with conventional methods.
Contact
LOCATION
Kassiopis 10 Str, 17237
Ymittos, Greece
ORTHOPAEDICS / SPINE / NEURO
Alecta Spine Fixation Systems
Biongraft Synthetic Bone Substitutes
Biongraft Bone Cements
Hemalimit Haemostats
DENTAL
Biongraft Synthetic Bone Substitutes
Resorbable Barrier Membranes